Cal 2000 Calibration Gas Instrument (750-0603-00)

Cal 2000 Calibration Gas Instrument (750-0603-00)

Gases supported
CI2
CIO2
H2
H2S
HCN
Specification
Chlorine Micro-Cell (CI2): 0.05 - 1.0 PPM
Chlorine (CI2): 0.5 - 50.0 PPM
Chlorine Dioxide (CIO2): 0.5 - 5.0 PPM
Hydrogen (H2): 0.5 - 50.0 PPM
Hydrogen Cynadine (HCN): 0.5 - 50.0 PPM
Hydrogen Sulfide Micro-Cell (H2S): 0.05 - 1.0 PPM
Hydrogen Sulfide (H2S): 0.5 - 50.0 PPM
  • A flexible and accurate instrument, providing unique cost savings vs, cylinders
  • From 50ppb to 50ppm, user selectable
  • Mass flow feedback provides sample draw calibration capabilities up to 5 lpm.
  • No storage of gas required, generate when and how much you need
  • No shelf life problems, no wastage, no recycling of cylinders
  • Non hazardous and easy to transport
  • 50 and 100 hour sources available.
  • English, French, German and Spanish user interfaces are available.
  • CSA, ATEX certified and intrinsically safe. NIST certified.
  • Brochure download

Accurate Calibration Gas Generation - The Cal 2000 provides unmatched versatility and accuracy in calibration gases. Field replaceable calibration gas sources (generating cells) provide a calibration standard for accurately testing Chlorine, Chlorine Dioxide, Hydrogen, Hydrogen Cyanide, and Hydrogen Sulfide gas detectors with a single instrument.

Cal Gas at a Fraction of the Cost - The Cal 2000 is microprocessor controlled, and has an LCD display allowing field adjustable gas concentrations and flow rates. The sources are interchangeable and field replaceable. Best of all, the Cal 2000 provides up to 100 times as much calibration gas as a disposable cylinder at a fraction of the cost. The electrochemical generating cells do not degrade.

Extreme Flexibility - The Cal 2000 instrument has a built-in mass flow sensor that automatically compensates for altitude and temperature. The mass flow sensor combined with the instruments' internal pump, provide extreme flexibility for calibrating both diffusion and sample draw detection systems.

Air Flow Rate (with internal pump):

0.2 to 1 LPM

Sample Draw Rate (with pump disabled):

0.1 to 5 LPM

Source Life:

50 or 100 hours

Warm-up Time (to 90%):

Approx. 5 minutes

L x W x H:

8.50 x 4.25 x 3.00" (21.59 x 10.8 x 7.62 cm)

Weight:

3 lb. (1360 g)

Operating Temperature:

0° C to 50° C

Relative Humidity (intermittent use):

0 - 100%

Accuracy:

±10%

Repeatability:

±5%

Battery Power:

4 alkaline "C"

Battery Life:

10 hours (at .5 lpm flow rate)