CAL 2000
Chlorine : | .05 - 50 PPM |
Chlorine Dioxide : | .5 - 5 PPM |
Hydrogen : | .05 - 50 PPM |
Hydrogen Cyanide : | .05 - 50 PPM |
Hydrogen Sulfide : | .05 - 50 PPM |
Nitrogen Dioxide : | .05 - 50 PPM |
Electrochemical Ammonia : | .05 - 100 PPM |
Accurate Calibration Gas Generation
The Cal 2000 provides unmatched versatility and accuracy in certified calibration gases.
Field replaceable calibration gas sources (generating cells) provide a calibration standard for accurately testing Chlorine, Chlorine Dioxide, Hydrogen, Hydrogen Cyanide, and
Hydrogen Sulfide gas detectors with a single instrument.
Cal Gas at a Fraction of the Cost
The Cal 2000 is microprocessor controlled and has an LCD (display) allowing field adjustable gas concentrations and flow rates. The sources are interchangeable and field replaceable.
Best of all, Cal 2000 provides up to 100 times as much calibration gas as a disposable
cylinder at a fraction of the cost. The electrochemical generating cells do not degrade over time.
Extreme Flexibility
The Cal 2000 instrument has a built-in mass flow sensor that automatically compensates for altitude and temperature. A mass flow sensor, combined with the instruments' internal pump, provides extreme flexibility for calibrating both diffusion and sample draw detection systems.
CSA NRTL/C Exia T-6 approved intrinsically safe with CE mark and ATEX Certification.
SKU: 750-0603-00
About This Product : | A powerful calibration gas system offering adjustable or fixed concentrations. |
Concentration : | Adjustable |
Flow rate : | 0.2 to 1 LPM Demand flow capable |
Certifications : | ATEX CE CSA |
Accuracy : | +/-5% or +/-10% |
Multiple Languages : | |
Chlorine : | .05 - 50 PPM |
Chlorine Dioxide : | .5 - 5 PPM |
Hydrogen : | .05 - 50 PPM |
Hydrogen Cyanide : | .05 - 50 PPM |
Hydrogen Sulfide : | .05 - 50 PPM |
Nitrogen Dioxide : | .05 - 50 PPM |
Electrochemical Ammonia : | .05 - 100 PPM |
Air flow rate (with internal pump) |
0.2 to 1 LPM |
Sample draw rate (with pump disabled) |
0.2 to 5 LPM |
Useful source life |
10, 50 or 100 hours |
Warm-up time (to 90%) |
Approximately 5 minutes |
L x W x H |
8.50 x 4.25 x 3.00' (21.59 x 10.8 x 7.62 cm) |
Weight |
3 lb. (1360 g) |
Operating temperature |
0° C to 50° C |
Relative humidity (intermittent use) |
0 -100% |
Accuracy |
±10% (+/- 5% available) |
Repeatability |
±5% |
Battery power |
4 alkaline 'C' |
Battery life |
10 hours (at .5 LPM flow rate) |
Item Description |
Capacity (Hrs.) |
PPM |
Part Number |
---|---|---|---|
Chlorine (Cl2) |
10 50 100 |
0.5 - 50 |
510-2000-10 510-2000-00 510-2000-20 |
|
10 50 100 |
0.05 - 1.0 |
510-2000-15 510-2000-05 510-2000-25 |
Chlorine Dioxide (ClO2) |
10 50 100 |
0.5 – 5 |
510-2060-10 510-2060-00 510-2060-20 |
Hydrogen (H2) |
10 50 100 |
0.5 – 50 |
510-2090-10 510-2090-00 510-2090-20 |
Hydrogen Sulfide (H2S) |
10 50 100 |
0.5 – 50 |
510-2050-10 510-2050-00 510-2050-20 |
|
10 50 100 |
0.05 - 1.0 |
510-2050-15 510-2050-05 510-2050-25 |
Hydrogen Cyanide (HCN) |
10 50 100 |
0.5 – 50 |
510-2070-10 510-2070-00 510-2070-20 |
|
10 50 100 |
0.1 - 2.0 |
510-2070-15 510-2070-05 510-2070-25 |
Electrochemical Ammonia (NH3) |
10 50 |
0.5 - 100 | |
Nitrogen Dioxide (NO2) |
10 50 |
0.5 - 50 |
Item Description |
Part Number |
---|---|
Accessories |
|
Hard body carrying case, CAL 2000, CAL 2000 LT |
730-0615-00 |
Continuous operation adapter, 115VAC with US plug |
362-0600-00 |
ACD Screwdriver |
243-0101-00 |
Replacement Parts |
|
Electrolyte, ClO2, 15 ml vial, 25 pack |
193-0101-25 |
Electrolyte, ClO2, 15 ml vial, 10 pack |
193-0101-10 |
Electrolyte, ClO2, 15 ml vial, 5 pack |
193-0101-05 |
Charcoal filter element, package of 12 |
150-0131-00 |
Nylon carrying case, CAL 2000, CAL 2000 LT |
730-0603-00 |
Electrolyte, ClO2, 15 ml vial |
193-0101-01 |
Hose, with quick connect, 5' |
715-0405-0X |
Charcoal filter element |
150-0121-00 |
Hose connector, insert (hose barb) quick connect |
113-0402-00 |
Outlet fitting, body (1/8 NPT) quick connect |
113-0400-00 |
Plunger feet fastener |
106-0603-00 |