Industrial Safety Sensors
Industrial gas sensors are purposefully designed to measure a variety of toxic and combustible gases to help keep workers safe in harsh commercial and factory environments.
The CityceL electrochemical sensor range — iSeries, 3, 4, 5 and 7 Series, MicroceL and Sensoric — joins the catalogue with UK stock and cross-reference support.
Industrial Safety Sensors
Ammonia 6
- Sensoric 3E 1000 SE Ammonia (NH3) Sensor
- Sensoric 3E 100 Ammonia (NH3) Sensor
- Sensoric 3E 1000 Ammonia (NH3) Sensor
- Sensoric 3E 5000 SE Ammonia (NH3) Sensor
- Sensoric 3E 500 SE Ammonia (NH3) Sensor
- Sensoric 3E 100 SE Ammonia (NH3) Sensor
Carbon Monoxide Sensors 32
- Carbon Monoxide Intelligent Series Gas Sensor (iseries)
- 1-Series 1CO Carbon Monoxide (CO) Sensor
- CiTiceL 3ME/F Carbon Monoxide (CO) Sensor
- CiTiceL A3E/D Carbon Monoxide (CO) Sensor
- CiTiceL T3F/F Carbon Monoxide (CO) Sensor
- CiTiceL A3E/F Carbon Monoxide (CO) Sensor
- CiTiceL 3M Carbon Monoxide (CO) Sensor
- CiTiceL A2E/F Carbon Monoxide (CO) Sensor
- CiTiceL A3ME/F Hydrogen Compensated Carbon Monoxide (CO-H2) Sensor
- CiTiceL T3E/F Carbon Monoxide (CO) Sensor
- CiTiceL A3ME/D Hydrogen Compensated Carbon Monoxide (CO-H2) Sensor
- CiTiceL A3CO Carbon Monoxide (CO) Sensor
- CiTiceL 4CF+ Carbon Monoxide (CO) Sensor
- CiTiceL 4CM Carbon Monoxide (CO) Sensor
- ECO-SURE X Carbon Monoxide (CO) Sensor
- CiTiceL 4MF Carbon Monoxide (CO) Sensor
- ECO-SURE 2E Carbon Monoxide (CO) Sensor
- CiTiceL 2CF3 Carbon Monoxide (CO) Sensor
- CiTiceL 4COSH Carbon Monoxide / Hydrogen Sulfide (CO/H2s (COSH)) Sensor
- CiTiceL 4LXH Carbon Monoxide (CO) Sensor
- CiTiceL 4F Carbon Monoxide (CO) Sensor
- CiTiceL 5F Carbon Monoxide (CO) Sensor
- CiTiceL A5F Carbon Monoxide (CO) Sensor
- CiTiceL A5F+ Carbon Monoxide (CO) Sensor
- CiTiceL 5MF Carbon Monoxide (CO) Sensor
- CiTicel TCO Carbon Monoxide (CO) Sensor
- CiTiceL A7E Carbon Monoxide (CO) Sensor
- CiTiceL 7EF Carbon Monoxide (CO) Sensor
- CiTiceL A7EF Carbon Monoxide (CO) Sensor
- CiTiceL 7E Carbon Monoxide (CO) Sensor
- AQ3CO Sensor - Carbon Monoxide (CO) Gas Sensor
- Honeywell AQ7CO Carbon Monoxide CO 7-Series Sensor
Chlorine 4
- CiTiceL 3MCLH Chlorine (Cl2) Sensor
- CiTiceL T3CLH Chlorine (Cl2) Sensor
- CiTiceL 4CL Chlorine (Cl2) Sensor
- Sensoric 3E 10 Chlorine (Cl2) Sensor
Ethylene Oxide Sensors 3
- 3ETO CiTiceL® Ethylene Oxide (C2 H4 O) Gas Sensor
- CiTiceL 4ETO Ethylene Oxide (C2H4O) Sensor
- CiTiceL 7ETO Ethylene Oxide (C2H4O) Sensor
Hydrogen Sulphide Sensors 17
- Hydrogen Sulfide (H2S) Sensor: iH2S
- 1-Series 1H2S Hydrogen Sulfide (H2S) Sensor
- CiTiceL 3MH Hydrogen Sulfide (H2S) Sensor
- CiTiceL T3H Hydrogen Sulfide (H2S) Sensor
- CiTiceL 3HH/LM Hydrogen Sulfide (H2S) Sensor
- CiTiceL 4H Hydrogen Sulfide (H2S) Sensor
- CiTiceL 4HS+ Hydrogen Sulfide (H2S) Sensor
- CiTiceL 4HS/LM Hydrogen Sulfide (H2S) Sensor
- CiTiceL 4H/LM Hydrogen Sulfide (H2S) Sensor
- CiTiceL 7HH Hydrogen Sulfide (H2S) Sensor
- CiTiceL 7HHLM Hydrogen Sulfide (H2S) Sensor
- CiTiceL 7H Hydrogen Sulfide (H2S) Sensor
- CiTiceL 7HLM Hydrogen Sulfide (H2S) Sensor
- Sensoric 3E 2000 S Hydrogen Sulfide (H2S) Sensor
- Sensoric 2E 50 S Hydrogen Sulfide (H2S) Sensor
- Sensoric 3E 100 S Hydrogen Sulfide (H2S) Sensor
- Sensoric 3E 100 Hydrogen Sulfide (H2S) Sensor
Nitric Oxide 11
- CiTiceL 3MNF/F Nitric Oxide (NO) Sensor
- CiTiceL T3NT Nitric Oxide (NO) Sensor
- CiTiceL 3NF/F Nitric Oxide (NO) Sensor
- CiTiceL T3NF/F Nitric Oxide (NO) Sensor
- CiTiceL 3NT Nitric Oxide (NO) Sensor
- CiTiceL 4NT Nitric Oxide (NO) Sensor
- CiTiceL 5NF Nitric Oxide (NO) Sensor
- CiTiceL 5NFL Low Range Nitric Oxide (NO) Sensor
- MediceL MNO2 & MNO2B Nitric Oxide (NO) Sensor
- CiTiceL 7NT Nitric Oxide (NO) Sensor
- Sensoric 3E 100 Nitric Oxide (NO) Sensor
Nitrogen Dioxide Sensors 6
- CiTiceL 3ND Nitrogen Dioxide (NO2) Sensor
- CiTiceL 3NDH Nitrogen Dioxide (NO2) Sensor
- CiTiceL 3MNDH Nitrogen Dioxide (NO2) Sensor
- CiTiceL T3ND Nitrogen Dioxide (NO2) Sensor
- CiTiceL T3NDH Nitrogen Dioxide (NO2) Sensor
- CiTiceL MND-1S Nitrogen Dioxide (NO2) Sensor
Oxygen 10
- City Technology ISeries Intell IO2 Datasheet
- 1-Series 1O2 Oxygen (O2) Sensor
- 2FO CiTiceL® Oxygen (O2 ) Gas Sensor
- CiTiceL 4OXLL Oxygen (O2) Sensor
- CiTiceL 4OXV Oxygen (O2) Sensor
- CiTiceL 5OXLL Oxygen (O2) Sensor
- CiticeL AO2 Oxygen (O2) Sensor
- CiTiceL 5FO Oxygen (O2) Sensor
- CiTiceL T7OX-V Oxygen (O2) Sensor
- CiTiceL 7OXV Oxygen (O2) Sensor
Phosphine 3
- Sensoric 3E 5 LT Phosphine (PH3) Sensor
- Sensoric 3E 5 F LT Phosphine (PH3) Sensor
- 4PH-Fast CiTiceL® Phosphine (PH3 ) Gas Sensor
Sulphur Dioxide 19
- 1-Series 1SO2 Sulfur Dioxide (SO2) Sensor
- CiTiceL T3SH Sulfur Dioxide (SO2) Sensor
- CiTiceL 3SF/F Sulfur Dioxide (SO2) Sensor
- CiTiceL 3MSF Sulfur Dioxide (SO2) Sensor
- CiTiceL 3ST/F Sulfur Dioxide (SO2) Sensor
- CiTiceL T3ST/F Sulfur Dioxide (SO2) Sensor
- CiTiceL 3SH Sulfur Dioxide (SO2) Sensor
- CiTiceL 3SC Sulfur Dioxide (SO2) Sensor
- CiTiceL A3ST/F Sulfur Dioxide (SO2) Sensor
- CiTiceL T3S/F Sulfur Dioxide (SO2) Sensor
- CiTiceL 3SF Sulfur Dioxide (SO2) Sensor
- CiTiceL 4S Sulfur Dioxide (SO2) Sensor
- CiTiceL 5SF Sulfur Dioxide (SO2) Sensor
- CiTiceL 5SC Sulfur Dioxide (SO2) Sensor
- CiTiceL 5SF/F Sulfur Dioxide (SO2) Sensor
- CiTiceL 7ST/F Sulfur Dioxide (SO2) Sensor
- CiTiceL 7SH Sulfur Dioxide (SO2) Sensor
- AQ3STF Sensor - Sulfur Dioxide (SO2) Gas Sensor
- Honeywell AQ7SO2 Sulfur Dioxide SO2 7-Series Sensor
Honeywell City Technology Industrial Gas Sensor
What is industrial gas sensors?
Industrial gas sensors are purposefully designed to measure a variety of toxic and combustible gases to help keep workers safe in harsh commercial and factory environments.
Are the iseries sensors interchangeable? If so, how and why?
All iseries sensors have the same form factor, pin-out, supply voltage and communication protocol, hence they are interchangeable.
- All sensors in the range will work with a supply voltage from 3.1 V to 3.3 V (between V+ and V-)
- The sensor has a UART protocol to communicate with the instrument with chip select option
- All intelligent sensors have the same dimensions and communication protocol, regardless of the type of technology
What is a pre-calibrated sensor?
All iseries sensors are calibrated during manufacturing, when the calibration data is programmed into the sensor. The sensors are fully calibrated when the sensors are installed using the recommended sealing and mounting proceedings (refer to sensor mounting application note). For the calibration to be valid in all instrument types, it is often necessary to compensate for the effects of external replaceable membranes, pumps or sampling systems on the sensor reading. The effects of these are very dependent on the gas type. To account for these effects, a compensation factor (also called User Factor) must be implemented. All iseries sensors are pre-calibrated. A pre-calibrated sensor becomes fully calibrated when a User Factor (UF) measurement has been provided for the instrument, and Honeywell has inputted the User Factor into an allocated User Factor Index (this process is done during manufacturing). The defined UF will help identify what type of instrument it is, and in this manner, the installed sensor will be fully compensated and calibrated.
How does OEM lock work? How do I get it to work for me?
The OEM lock is a lock code that is set between your instrument and sensor. It allows you to verify that no other sensor (other than yours) can work on your instrument, i.e. the sensor needs to be purchased directly from you. OEM code is set by Honeywell during sensor manufacturing with the code to be provided by the OEM.
Can I solder the sensor?
Under no circumstances should intelligent sensor pads be soldered to, as this can cause irreversible damage to the sensor.
What is the resolution of the ADC?
The ADC converter is 16 bits with multiple measuring ranges; however, the output resolution depends on the type of sensor, for the first wave of sensors, the resolutions are:
- CO: 1 ppm
- H2S: 0.1 ppm
- SO2: 0.1 ppm
- LEL: 1% LEL
- O2: 0.1% O2
Specification, Not Order Taking
Tell us the detector, the target gas, the alarm level and the environment. We come back with the part that actually works, and the reason.